Commercial
Basement Car Park Waterproofing — Commercial Building
Two-level basement car park with seepage through the walls, floor and construction joints.
01The challenge
Every monsoon, water came through the retaining walls and construction joints. Finishes were peeling, the floor stayed wet, and the electrical and pump rooms were at risk.
02Our solution
Our engineers mapped every wet patch and joint first. Active leaks were sealed by pressure injection, joints were cut out and rebuilt, and the walls and slab were treated from the inside with a two-coat waterproofing system that works against water pressure from outside. Drains and sumps were checked and cleared.
The car park stayed open in sections, so tenants could keep parking while we worked.
03The result
The basement stayed dry through the following monsoon. The car park and services rooms are back in normal use.
More projects
Epoxy Flooring — Production & Packing Hall
A seamless, easy-to-clean floor for a new production and packing hall.
Case studyRoof Waterproofing & Heat Insulation — Apartment Building
Leaking, hot top-floor flats in a 10-storey apartment building.
Case studyColumn Strengthening & Structural Repair — Factory Building
Repair and strengthening of corrosion-damaged columns in an ageing factory building.
Case studyBook a site visit
Have a project in mind?
Tell us what is leaking, cracking or wearing out. We inspect the site, find the cause and send a clear written quotation.